TRU Block Ultra

TRU Block ™ ULTRA Performance TRU Block ™ ULTRA is a powerful HAMA and RF blocking buffer that can be used in double mouse monoclonal sandwich assays to reduce assay interference. Its advanced performance has been proven by customers who use this blocker in commercial ELISA and Lateral Flow assays to improve assay performance. In-house studies (shown below) have also demonstrated TRU Block ™ ULTRA to be an effective blocker compared to Mouse IgG and a Competitor’s active HAMA blocker.

CA19-9 Assay & BRH56382 HAMA Sera

CA19-9 Assay & SD386-1 HAMA Sera

2.5

3

Unblocked HAMA Signal

Unblocked HAMA Signal

2.5

2

2

1.5

1.5

1

1

0.5

0.5

No Blocker

TRU Block™ Competitor

Mouse IgG 1.25μg/mL 0.625μg/mL

No Blocker

TRU Block™ Competitor

Mouse IgG 1.25μg/mL 0.625μg/mL

5μg/mL 2.5μg/mL

No Blocker

5μg/mL 2.5μg/mL

No Blocker

HAMA Interference

FSH Assay & BRH56382 HAMA Sera

FSH Assay & Roche (Type 1) HAMA Sera

0.5 1 1.5 2 2.5 3

0.2 0.4 0.8 0.6 1.0 1.4 1.2 1.6

Unblocked HAMA Signal

Unblocked HAMA Signal

No Blocker

TRU Block™ Competitor

Mouse IgG 1.25μg/mL 0.625μg/mL

No Blocker

TRU Block™ Competitor

Mouse IgG 1.25μg/mL 0.625μg/mL

5μg/mL 2.5μg/mL

5μg/mL 2.5μg/mL

No Blocker

No Blocker

CA19-9 Assay & A12916H RF Sera (Diluted 1:4)

In-house RF Assay & A01270H RF Sera (Diluted 1:5) Unblocked RF Signal

1.2

0.2 0.4 0.8 0.6 1.0 1.4 1.2 1.6

1

Unblocked RF Signal

0.8

0.6

RF Interference

0.4

0.2

No Blocker

TRU Block™ Competitor

Mouse IgG

No Blocker

TRU Block™ Competitor Mouse IgG Rabbit IgG 5μg/mL 1.25μg/mL 2.5μg/mL

5μg/mL

1.25μg/mL 2.5μg/mL

No Blocker

No Blocker

ASSAY METHOD: Three different double mouse monoclonal sandwich assays (a Commercial CA19-9, a commercial FSH and an in-house RF assay) were used to compare the performance of TRU Block ™ ULTRA against Mouse IgG and a Competitor’s active HAMA blocker. To quantify the relative amount HAMA or RF activity in each human sera sample within an assay, the assay was performed as per the manufacturer’s instructions using a sample diluent buffer containing no Mouse IgG or other blocker. Blocking solutions containing either TRU Block ™ ULTRA, Mouse IgG or Competitor Blocker were prepared using the same sample diluent buffer at four different concentrations (5 ml, 2.5 ml, 1.25 ml and 0.625 μg/ml). The effectiveness of each blocker was determined by the relative suppression HAMA or RF signal (i.e. comparing the absorbance of samples with no blocker to those with various blockers) . Native HAMA positive sera samples were obtained from Scantibodies, Inc. (SD386-1) and BioReclamation (BRH56382). Another sample was obtained from Roche (Roche Type 1) which contains pooled normal human serum spiked with Roche proprietary HAMA. RF sera samples (MLS Cat No. A12916H and A01270H) were obtained internally and are available for purchase from Meridian’s product catalog (www.meridianlifescience.com). The study results demonstrate that TRU Block™ ULTRA is equivalent to or better than a Competitor’s active blocker on all HAMA and RF sera samples tested.

Life Science Division 5171 Wilfong Road, Memphis, TN 38134 901-382-8716 • 800-327-6299 • info@meridianlifescience.com

Connect with us:

05/19

www.meridianbioscience.com/lifescience

Powered by