Ambient-temperature Stable LAMP Master Mixes

Inhibitor Tolerant LAMP & RT-LAMP Mixes

Saliva-Specific Mixes

Saliva

Saliva is ideal for use as a diagnostic specimen as it contains hormones, antibodies, growth factors, enzymes and microbes that can be used as biomarkers for disease detection. Saliva is easy-to-collect and allows non-invasive and simple sample collection/logistics, making it perfect for point of care testing. However, due to the low concentration of analytes and high concentration of inhibitors in saliva, its use in molecular diagnostics has been limited. Isothermal amplification such as LAMP is very tolerant to inhibitors and the simple workflow allows fast, sensitive, reliable results in clinical diagnosis.

PRODUCT

CAT NO. VOLUME REACTIONS

5 mL 800 Rxns 50 mL 8,000 Rxns 5 mL 800 Rxns 50 mL 8,000 Rxns

Lyo-Ready Direct DNA LAMP Saliva Mix

MDX134

Lyo-Ready Direct RNA/DNA LAMP Saliva Mix

MDX135

Meridian’s new Lyo-Ready Direct DNA LAMP and RNA/DNA LAMP Saliva mixes are the newest advancement in molecular reagent technology and combine the benefits of a highly inhibitor-tolerant mix, with robust isothermal amplification, to enable direct detection using crudely processed samples. The mixes are uniquely designed to overcome saliva and sputum inhibitors and they do not require a DNA or RNA purification step to purify a patient sample. In addition, the 4x concentrated master mixes are formulated with lyo-excipients which are optimized for freeze-drying to create ambient-temperature stable assays. By using innovative ready-to-use isothermal master mixes such as Lyo-Ready Direct DNA LAMP or RNA/DNA LAMP Saliva mix, assay development time for a new ultra-sensitive direct saliva assay is rapid, simple and efficient. Perfect for increasing your competitive edge and capturing value faster in the rapidly growing point-of-care market.

High Inhibitor Tolerance and Fast Amplification To Deliver Quicker Time-to-Results (TTR) in Saliva, Sputum and Samples Containing Universal Transport Media (Utm)

Lyo-Ready Direct DNA LAMP Saliva (MDX134)

HSV2

CMV

ADV

70

70

70

60

60

60

50

50

50

40

40

40

30

30

30

20

20

20

10

10

10

0

0

0

0% inhibitor

30% saliva

30% UTM + Sputum

30% VTM

NTC

0% inhibitor

30% saliva

30% UTM + Sputum

0% inhibitor

30% saliva 30% UTM + Sputum

30% VTM NTC

30% VTM

NTC

Lyophilized | NEB WarmStart®

Primers for CMV, ADV or HSV-2 were added to Lyo-Ready Direct DNA LAMP Saliva (MDX134) and lyophilized ( blue ) or added to NEB WarmStart® ( orange ) and kept as a liquid. The mixes were amplified using inactivated Cytomegalovirus (CMV), Adenovirus (ADV) or Herpes simplex virus 2 (HSV2). Reactions were prepared in the presence of 30% human saliva, 30% Universal Transport Medium (UTM) + an artificial sputum swab and Viral Transport Medium (VTM). All reactions were incubated at 65 °C for 60 minutes, and average time to results (TTR) was measured at 1:10 of end fluorescence. Error bars represent the standard deviation across four technical replicates. Results show that MDX134 ( blue ) has a shorter TTR than NEB WarmStart® ( orange ) amplification across all three sample orange types. The data suggests that MDX134 performs better with faster amplification across the range of inhibitors.